Vigileo SV, CO and SVV¶
Stroke volume, cardiac output and stroke volume variation.
Stub
Imported from the time-source table; the full page is still to be written.
| Name in the dataset | Vigileo/SV |
| Type | numeric |
| Device | Vigileo |
| Stamped by | Recorder PC clock |
Measurement space¶
Time side (as stamped): the true time lies between -45 s and -2 s from the stamp: the delay range plus the interval one value describes.
Time¶
From UTC to the stored time stamp¶
Derived from this signal's timing table; a written chain is still to come.
The clock path first (UTC to the clock that stamps or spaces the samples), then the signal's own path to its stored time. Each bar: the time shift or error the step introduces (pale) and what is left after the atlas's correction (solid), on a log scale; dashed when estimated or assumed.
The reference every chain starts from.
Windows time synchronisation to the hospital's time server every 8–24 h (assumed), drifting a few ppm in between. Not observable in the release: dates are shifted to 2100. No step of 0.5 s or more was found.
Delay from the end of the interval a value describes to its stamp.
Stored time stamp
The width of the interval one value or sample stands for.
Timing¶
Against the working reference. Delay: from the end of the interval a value describes to its stamp. Interval: how wide that interval is.
| Form | Delay | Interval | Clock domain | Status | Evidence |
|---|---|---|---|---|---|
| as stamped (default) | 2 s – 25 s | 20 s | Vigileo | measured | SVV vs arterial PPV: aligned in 25 of 343 cases, |
Combine it with other signals in the synchronisation planner.
Value¶
Its value side is still to be described.
Studies¶
| Study | Date | Status | Summary |
|---|---|---|---|
| Value resolution of every signal | 2026-10-19 | draft | How finely every waveform and numeric track in the release records its values. The SNUADC waveforms are 10-bit codes, though VitalRecorder's documentation describes the SNUADC as 12-bit; Primus waveforms use about 10 bits of 12; BIS EEG is a 16-bit grid of 0.05 µV. Numerics are 32-bit floats on decimal grids of 1, 0.1, 0.01 or 0.001, one per track; settings sit on coarser grids of 10 or 100. |
| Rare devices against SNUADC | 2026-10-13 | current | CardioQ, EV1000, Vigileo and Vigilance each get a link to the SNUADC timeline: beat matching for the CardioQ, mean arterial pressure alignment for the EV1000 and Vigileo, and a long-window fit for Vigilance's averaged heart rate. |