Central lab result time¶
Time stamp of a central laboratory result in the lab table.
Stub
Imported from the time-source table; the full page is still to be written.
| Name in the dataset | lab_data (central lab) |
| Type | event |
| Device | Clinical records |
| Stamped by | Hospital records clock |
Measurement space¶
Time side (lab timestamp): the true time lies between -1441 s and -480 s from the stamp: the delay range plus the interval one value describes.
Time¶
From UTC to the stored time stamp¶
The clock path first (UTC to the clock that stamps or spaces the samples), then the signal's own path to its stored time. Each bar: the time shift or error the step introduces (pale) and what is left after the atlas's correction (solid), on a log scale; dashed when estimated or assumed.
The reference every chain starts from.
The laboratory and anaesthesia record systems keep hospital time (KST). Their offset from UTC and from the recorder PC is not observable in the release, which shifts every case to 2100.
Blood draw
Drawn (often not from the arterial line), sent to the central lab and logged there about 8–24 min later.
Result known
The result follows an unrecorded turnaround.
Stored lab time
Whole seconds, one time per specimen.
Timing¶
Against the working reference. Delay: from the end of the interval a value describes to its stamp. Interval: how wide that interval is.
| Form | Delay | Interval | Clock domain | Status | Evidence |
|---|---|---|---|---|---|
| lab timestamp (default) | 8 min – 24 min | 1 s | Clinical and lab records | measured | ~8-24 min after the access (median ~14; weak); result after an unrecorded turnaround |
| draw time from arterial access | 10 s – 100 s | 28 s – 117 s | Clinical and lab records | estimated | access 28-117 s (p10-p90); matched 0-15 min (gas) or 0-30 min (central) before |
Combine it with other signals in the synchronisation planner.
Value¶
Its value side is still to be described.
Parameters¶
| Parameter | Value | Status | From |
|---|---|---|---|
| Central lab timestamp after the draw | about 8–24 min (median about 14; weak, mostly chance matches) | estimated | What the lab timestamp marks |
Observations¶
| Observation | Status | Summary |
|---|---|---|
| The lab time is neither the draw nor the result | established | VitalDB's lab timestamp marks the specimen (logged at the lab, or entered from a theatre analyser): minutes after the draw and before the result, whose time is not recorded. |
Studies¶
| Study | Date | Status | Summary |
|---|---|---|---|
| What the lab timestamp marks | 2026-10-13 | current | VitalDB's lab time is a per-specimen timestamp: not the draw, and not the result. Blood gases are stamped 3–12 minutes after the draw, central-lab panels about 8–24 minutes after it, and the result follows a turnaround the release does not record. |
| Arterial line accesses in the pressure waveform | 2026-10-11 | current | Flushes, zeroing and blood draws leave clear signatures in the arterial pressure. A detector finds them in the waveform alone (about one access per hour) and matches 77% of lab draws to an access within 15 minutes, against 26% for random times. |