CardioQ clock¶
The CardioQ's own clock; the recorder re-anchors its stamps about every 5 minutes.
Stub
Imported from the time-source table; the full page is still to be written.
| Type | oscillator |
| Nominal | Waveform sample clock |
| Kept by | CardioQ |
Description¶
The CardioQ's own clock; the recorder re-anchors its stamps about every 5 minutes.
Route to UTC¶
The route the atlas trusts most (2 links; its weakest link is measured apart from the link to UTC that every clock shares):
link measured CardioQ against the recorder PC: corrected every at most about 300 s; about 40 re-anchors per case
Where every route ends.
Independent checks. 3 other routes reach UTC; where they meet, the offsets must close around the loop:
- CardioQ clock (CardioQ against SNUADC) → SNUADC sample clock (SNUADC (frequent-correction mode) against the recorder PC) → Recorder PC clock (Recorder PC against UTC) → UTC
- CardioQ clock (CardioQ against SNUADC) → SNUADC sample clock (SNUADC (step mode) against the recorder PC) → Recorder PC clock (Recorder PC against UTC) → UTC
- CardioQ clock (CardioQ against SNUADC) → SNUADC sample clock (BIS against SNUADC) → BIS clock (BIS against the recorder PC) → Recorder PC clock (Recorder PC against UTC) → UTC
Plan. Re-anchored about every 5 minutes against the PC, and matched beat by beat to SNUADC per stretch; the three-way arterial pressure loop with the EV1000 and SNUADC closes. Enough for second-level alignment; no drift within a stretch is modelled.
Links to other clocks¶
| Link | Clock | Against | Modes | Rate | Corrected every | Status |
|---|---|---|---|---|---|---|
| CardioQ against the recorder PC | CardioQ clock | Recorder PC clock | all | — | at most about 300 s; about 40 re-anchors per case | measured |
| CardioQ against SNUADC | CardioQ clock | SNUADC sample clock | all | — | — | measured |
Variables spaced by this clock¶
Studies¶
| Study | Date | Status | Summary |
|---|---|---|---|
| Closing loops in the timing graph | 2026-10-13 | current | Where two independent routes reach the same clock, the offsets around the loop must sum to zero. Three measured loops close within their noise; the BIS loop closes up to a constant latency; the proposed EMR loop is not a loop at all. |
| Rare devices against SNUADC | 2026-10-13 | current | CardioQ, EV1000, Vigileo and Vigilance each get a link to the SNUADC timeline: beat matching for the CardioQ, mean arterial pressure alignment for the EV1000 and Vigileo, and a long-window fit for Vigilance's averaged heart rate. |
| Clock corrections in every file | 2026-10-11 | current | A scan of all 6,388 files for the jumps where the recorder re-synchronises a device's stamps. Each device type has its own correction signature; only SNUADC and BIS correct clearly enough to measure their drift. |
Tags: stub