Blood gas result time

Time stamp of a blood gas result in the lab table.

Stub

Imported from the time-source table; the full page is still to be written.

Name in the dataset lab_data (blood gas)
Type event
Device Clinical records
Stamped by Hospital records clock

Measurement space

Time side (lab timestamp): the true time lies between -731 s and -190 s from the stamp: the delay range plus the interval one value describes.

Time

From UTC to the stored time stamp

The clock path first (UTC to the clock that stamps or spaces the samples), then the signal's own path to its stored time. Each bar: the time shift or error the step introduces (pale) and what is left after the atlas's correction (solid), on a log scale; dashed when estimated or assumed.
The reference every chain starts from.
sync assumed
The laboratory and anaesthesia record systems keep hospital time (KST). Their offset from UTC and from the recorder PC is not observable in the release, which shifts every case to 2100.
Blood draw
processing measured 3.17 min – 12.2 min → 28 s – 117 s after correction · parameter, What the lab timestamp marks, Arterial line accesses in the pressure waveform
Blood is drawn from the arterial line (an access, 28–117 s long) and analysed in theatre or sent on. The specimen is stamped 3–12 min after the draw; the lab_draw label marks the matched access.
Result known
processing assumed
The result follows an unrecorded turnaround; a value is known no earlier than its timestamp plus that turnaround.
Stored lab time
stamping measured 1 s
Whole seconds, one time per specimen shared by every analyte of the panel.

Timing

Against the working reference. Delay: from the end of the interval a value describes to its stamp. Interval: how wide that interval is.

Form Delay Interval Clock domain Status Evidence
lab timestamp (default) 3.17 min – 12.2 min 1 s Clinical and lab records measured 3-12 min after the access (modes ~4, ~9 min); the value is known later
draw time from arterial access 10 s – 100 s 28 s – 117 s Clinical and lab records estimated access 28-117 s (p10-p90); matched 0-15 min (gas) or 0-30 min (central) before

Combine it with other signals in the synchronisation planner.

Value

Its value side is still to be described.

Parameters

Parameter Value Status From
Blood gas timestamp after the draw 7.2 min (p10–p90 3.2 to 12.2; two modes, 2–6 and 8–12 min) measured What the lab timestamp marks

Observations

Observation Status Summary
The lab time is neither the draw nor the result established VitalDB's lab timestamp marks the specimen (logged at the lab, or entered from a theatre analyser): minutes after the draw and before the result, whose time is not recorded.

Studies

Study Date Status Summary
What the lab timestamp marks 2026-10-13 current VitalDB's lab time is a per-specimen timestamp: not the draw, and not the result. Blood gases are stamped 3–12 minutes after the draw, central-lab panels about 8–24 minutes after it, and the result follows a turnaround the release does not record.
Arterial line accesses in the pressure waveform 2026-10-11 current Flushes, zeroing and blood draws leave clear signatures in the arterial pressure. A detector finds them in the waveform alone (about one access per hour) and matches 77% of lab draws to an access within 15 minutes, against 26% for random times.

Worked examples

Example Side Status Summary
End-tidal to arterial CO₂, and pulse oximetry against blood gas, at the right moment time draft For 4,281 blood gases, reading the monitor when the blood was drawn rather than at the lab stamp makes changes in end-tidal CO₂ track changes in arterial CO₂ far better (within-patient correlation 0.74 against 0.54), and agreement peaks exactly at the estimated draw. Oximetry shows the same timing (agreement peaks at the draw), but the 100% ceiling hides the size of the oximetry gradient for three gases in four.

Tags: stub