Infusion pump rates and volumes¶
Drug infusion rates and volumes from the pumps.
Stub
Imported from the time-source table; the full page is still to be written.
| Name in the dataset | Orchestra/PPF20_RATE |
| Type | numeric |
| Device | Infusion pumps |
| Stamped by | Recorder PC clock |
Measurement space¶
Time side (as stamped): the true time lies between -12 s and -0.1 s from the stamp: the delay range plus the interval one value describes.
Time¶
From UTC to the stored time stamp¶
Derived from this signal's timing table; a written chain is still to come.
The clock path first (UTC to the clock that stamps or spaces the samples), then the signal's own path to its stored time. Each bar: the time shift or error the step introduces (pale) and what is left after the atlas's correction (solid), on a log scale; dashed when estimated or assumed.
The reference every chain starts from.
Windows time synchronisation to the hospital's time server every 8–24 h (assumed), drifting a few ppm in between. Not observable in the release: dates are shifted to 2100. No step of 0.5 s or more was found.
Delay from the end of the interval a value describes to its stamp.
Stored time stamp
The width of the interval one value or sample stands for.
Timing¶
Against the working reference. Delay: from the end of the interval a value describes to its stamp. Interval: how wide that interval is.
| Form | Delay | Interval | Clock domain | Status | Evidence |
|---|---|---|---|---|---|
| as stamped (default) | 100 ms – 2 s | 1 s – 10 s | Infusion pumps | estimated | 1 s records; propofol start -> BIS<60 132 s median, none negative (497 cases) |
Combine it with other signals in the synchronisation planner.
Value¶
Its value side is still to be described.
Studies¶
| Study | Date | Status | Summary |
|---|---|---|---|
| Value resolution of every signal | 2026-10-19 | draft | How finely every waveform and numeric track in the release records its values. The SNUADC waveforms are 10-bit codes, though VitalRecorder's documentation describes the SNUADC as 12-bit; Primus waveforms use about 10 bits of 12; BIS EEG is a 16-bit grid of 0.05 µV. Numerics are 32-bit floats on decimal grids of 1, 0.1, 0.01 or 0.001, one per track; settings sit on coarser grids of 10 or 100. |
| Drug effects as a clock check | 2026-10-13 | current | Infusion pumps, the rapid infuser and the cerebral oximeter share no waveform with the reference. Drug effects that follow infusions at plausible delays (propofol to BIS in about 2 minutes, fluid to CVP in about 30 s) bound their clocks to well within a minute of the recorder. |
| Anaesthesia record times are rounded up | 2026-10-12 | current | Anaesthesia start and end entered on a 5-minute mark sit 90–290 s later, against device markers, than entries typed to the minute. Rounding up to the next 5 minutes fits every one of 11 markers better than rounding to the nearest or down. |
Worked examples¶
| Example | Side | Status | Summary |
|---|---|---|---|
| Charted propofol dose against the infusion pump | value | planned | The charted propofol bolus total against the volume the Orchestra pump records, as a check of the propofol heaping model and as a dose in mg/kg with its uncertainty. |
| Post-induction hypotension, from the charted start and from the devices | time | draft | The charted anaesthesia start comes a median 14 minutes before the patient is induced; measured from it, "hypotension within 20 minutes of induction" is found in 27% of 2,913 patients, against 51% from the devices' induction, and the label changes for a quarter of patients. |
Tags: stub