Intraoperative colloid¶
Intraoperative colloid (clinical table).
| Name in the dataset | intraop_colloid |
| Type | clinical |
| Stored in | clinical_data.csv |
| Unit | mL |
Description¶
Container sizes are exact counts; partial amounts estimated. Kidney question pending.
Measurement space¶
A vertical slice through the measurement space: how the true value is spread around any one recorded value. Its shape is uniform.
Time¶
This variable carries no time of its own in the dataset.
Value¶
| Model kind | colloid_rules: rule set by operation |
| Native step | 1 mL |
| Anchor | nearest (convention) |
In this release¶
How wide the true-value distribution is, record by record, over 531 of 6,388 records (all clinical rows) that have one. Computed with the pinned model, aggregates only.
| Median | p10 to p90 | |
|---|---|---|
| Standard deviation | 0 mL | 0 to 28.9 mL |
| 95% interval width | 0 mL | 0 to 95 mL |
| Mean minus recorded | 0 mL | 0 to 0 mL |
Anchor¶
Native recording unit, rounding to the nearest assumed; not tested (sparse or exact-count data). See what an anchor is and every variable's anchor.
Worked examples¶
| Example | Side | Status | Summary |
|---|---|---|---|
| Intraoperative fluid balance as a distribution | value | draft | Fluids in minus fluids out, each a heaped charted volume, as a distribution per case: the recording alone makes a balance uncertain by about ±60 mL, and by ±190 mL when the blood loss was written as a round 500 mL. |
Figures¶
Tags: generated, vitaldb-resolution