Recorder PC against UTC
The recorder PC keeps Windows time, synchronised to the hospital's time server every 8–24 hours. Its offset from UTC is assumed, not observed; no step of 0.5 s or more appears anywhere in the release.
Correction
Windows time synchronisation (NTP to the hospital time server) every 8–24 h is assumed. Whatever correction
it makes is smaller than 0.5 s: no simultaneous jump of every device of that size was found in any file
(Largest recorder PC clock step).
Parameters
Evidence
| Study |
Date |
Status |
Summary |
| Recorder PC clock steps and recording pauses |
2026-10-17 |
current |
A step of the recorder PC clock would move every device's stamps at once. Searching all 6,388 files for such simultaneous jumps found none of 0.5 s or more; what moves everything together is recording pauses. |