Partial pressure of CO₂¶
partial pressure of CO₂ (lab table).
| Name in the dataset | pco2 |
| Type | lab |
| Stored in | lab_data.csv |
| Stamped by | Hospital records clock |
| Unit | mmHg |
Description¶
Single resolution; no heaping in the whole-number screen.
Its time is the lab system's result time: see Blood gas result time and Central lab result time.
Measurement space¶
A vertical slice through the measurement space: how the true value is spread around any one recorded value. Its shape is uniform.
Time¶
Its time side is still to be described.
Value¶
| Model kind | uniform: single resolution; uniform over the rounding interval |
| Resolution | 1 mmHg, nearest |
| Native step | 1 mmHg |
| Anchor | nearest (convention) |
In this release¶
How wide the true-value distribution is, record by record, over 1,354 of 1,354 records (every lab row of 600 random cases) that have one. Computed with the pinned model, aggregates only.
| Median | p10 to p90 | |
|---|---|---|
| Standard deviation | 0.289 mmHg | 0.289 to 0.289 mmHg |
| 95% interval width | 0.95 mmHg | 0.95 to 0.95 mmHg |
| Mean minus recorded | 0 mmHg | 0 to 0 mmHg |
Anchor¶
Laboratory results rounded to the last reported digit; at most half the last digit. See what an anchor is and every variable's anchor.
Worked examples¶
| Example | Side | Status | Summary |
|---|---|---|---|
| End-tidal to arterial CO₂, and pulse oximetry against blood gas, at the right moment | time | draft | For 4,281 blood gases, reading the monitor when the blood was drawn rather than at the lab stamp makes changes in end-tidal CO₂ track changes in arterial CO₂ far better (within-patient correlation 0.74 against 0.54), and agreement peaks exactly at the estimated draw. Oximetry shows the same timing (agreement peaks at the draw), but the 100% ceiling hides the size of the oximetry gradient for three gases in four. |
Figures¶